EVA4000

HP Enterprise Virtual Array (EVA)´Â HPÀÇ irtualization ±â¼úÀ» ±¸ÇöÇÑ Á¦Ç°À¸·Î¼­, °í¼º´É, °í¿ë·®, °í°¡¿ë¼ºÀ» °®Ãá °¡»ó RAID ½ºÅ丮Áö ¼Ö·ç¼ÇÀÔ´Ï´Ù.
±¸ºÐ Ç׸ñ ±Ô°Ý ºñ°í
Interface ÀÎÅÍÆäÀ̽º ŸÀÔ 4Gb/s FC
1 ~ 4Gb/s FC HBA Áö¿ø
È£½ºÆ® /
µð½ºÅ© Æ÷Æ® ¼ö
4°³ / 4°³
2°³ ¾¿/Controller
¸Æ½Ã¸Ø È£½ºÆ® ¼ö 256 host connections
 
Controller ÃÖ´ë Á¦¾î µð½ºÅ© ¼ö 56°³ (EVA6K·Î È®Àå ½Ã ÃÖ´ë 112°³)
Dual Controller ±âÁØ
ÃÖ´ë È®Àå ¿ë·® 16.8 TB (w/300GB Disk Module)
300GB x 56°³
Áö¿ø RAID Level / Spare vRAID 0, 1, 5 / Spare Level 0, 1, 2 Áö¿ø  
Disk Drive ÀÎÅÍÆäÀ̽º ŸÀÔ
Fibre Channel Arbitrated Loops (FC-AL)
 
FC Disk 72GB 10K / 15K RPM
146GB 10K RPM / 15K RPM
300GB 10K RPM
(Dual-port 2Gb/s FC disk drives)
 
FATA Disk
500GB 7,200 RPM FATA disk
(Dual-port 2Gb FC Hybrid disk drive)
Fibre-ATA Disk
Disk
Enclosure
M5314B
3U, 14-bays for FC & FATA disk drive
EVA4000¿¡¼­ ÃÖ¼Ò 1°³ ~ 4°³±î Áö¿ø (EVA4000 2C1D ~ 2C4D µî)
ÃÖ¼Ò 8°³ ÀÌ»ó ÇÊ¿äÇϸç,
over 4 disks/Enclosure EVA6K 2C8D·Î È®Àå °¡´É
 
ÃÊ´ç over 141,000 IOPS
4G bps ±¤ ä³Î ÀÎÅÍÆäÀ̽º
(4°³ÀÇ Host Interfaces Á¦°ø)
4°³ÀÇ Disk Interfaces Á¦°ø
4 GB Cache Á¦°ø
ÄÁÆ®·Ñ·¯¿Í µð½ºÅ©¿ÍÀÇ ¿¬°áÀ» À§ÇÑ ±¤ ä³Î ·çÇÁ ½ºÀ§Ä¡ Á¦°ø
2°³ÀÇ Array ÄÁÆ®·Ñ·¯ °£ Fail-Over ¹× Fail-Back Áö¿ø
 
FC ½ºÀ§Ä¡¸¦ ÅëÇØ¼­ ¿ë·® È®Àå
±¤ ä³Î ½ºÀ§Ä¡ Cascading Áö¿ø
ÄÁÆ®·Ñ·¯ ½Ö ´ç ÃÖ´ë 56 ~ 112°³ÀÇ µð½ºÅ© ÀåÂø
72GB 146GB, 300GB FC Disk/ 500GB FATA µð½ºÅ© Áö¿ø (È¥¿ë ±¸¼º Áö¿ø)
ij½Ã ¹Ì·¯¸µ ¹× ¹èÅ͸® ¹é¾÷ Áö¿ø
vRAID 0, vRAID1, vRAID 5 Áö¿ø
Spare Level Áö¿ø
     
¸ðµç ºÎǰÀÌ ÇÖ Ç÷¯±× Áö¿ø
»óÀÌÇÑ RAID ·¹º§ È¥¿ë °¡´É
»óÀÌÇÑ ¿ë·®ÀÇ µð½ºÅ© È¥¿ë °¡´É
Command View EVA¸¦ ÅëÇÑ Web-Based·Î ÅëÇÕ °ü¸®
¿ø°Ý ¸ð´ÏÅ͸µ ¼­ºñ½º(ISEE) ¹«»ó Á¦°ø
 
2°³ÀÇ Array ÄÁÆ®·Ñ·¯ °£ Fail-Over ¹× Fail-Back Áö¿ø
ij½Ã ¹Ì·¯¸µ ¹× ¹èÅ͸® ¹é¾÷ Áö¿ø
Àü¿ø °ø±Þ±â ¹× ³Ã°¢ ÆÒ¿¡ ´ëÇÑ Redundancy Áö¿ø
vRAID 0, vRAID1, vRAID 5 Áö¿ø
Spare Level Áö¿ø
È£½ºÆ® ¾î´ðÅÍ °£ÀÇ Fail-Over Áö¿ø
 
 
Modular ÇüÅÂÀÇ ½ºÅ丮Áö È®Àå
Enclosure Ãß°¡ ¹× Storage cabinet ¿¬°á·Î È®Àå
Monolithic ÇüÅÂÀÇ ½ºÅ丮Áöó·³ Ãʱ⿡ ¿ë·®´ëºñ ÇÊ¿ä ÀÌ»óÀÇ ½ºÅ丮Áö ½Ã½ºÅÛÀ» ±¸¸ÅÇØ¾ß ÇÏ´Â °ú ÅõÀÚ¸¦ ¹æÁöÇϰí
  °í°´ÀÇ Ãʱâ ÅõÀÚºñ¿ëÀ» º¸È£Çϸ鼭 ÇâÈÄ ÇÊ¿äÇÑ ¿ë·®À» ÄÁÆ®·Ñ·¯¿Í ÇÔ²² È®ÀåÇÒ ¼ö ÀÖ´Â ¼Ö·ç¼ÇÀ» Á¦°ø
Dual Controller ±¸¼º ½Ã 2C1D ~ 2C8D È®Àå
 
EVA4000 Rack Configurations
(Upgrade to EVA6000 Configuration)
Model 2C1D 2C2D 2C3D 2C4D 2C8D
(EVA6K)
Controllers 2
2 2 2 2
Drive Enclosures 1
2 3 4 8
Disk Drives 14
28 42 56 112